Home > Suppliers Companies > Dyno Nobel Inc. > Products > Oil Field Explosives > FIRELINE 17/80 HMX LS EXPOSED
Dyno Nobel Inc.

FIRELINE 17/80 HMX LS EXPOSED

FIRELINE 17/80 HMX LS EXPOSED is a flexible High Temperature/High Pressure (HT/HP) cord specifically developed for encapsulated perforating systems, back-off or other “down hole” exposed service systems. It is our best detonating cord for use in caustic environments. The detonating cord utilizes the highest purity HMX explosive feedstock commercially available, “shrinkage resistant” construction and a special high temperature jacket. This jacket allows the cord to be exposed to well bore fluids at temperature and pressure.
FIRELINE 17/80 HMX LS EXPOSED
FIRELINE 17/80 HMX LS EXPOSED is a flexible High Temperature/High Pressure (HT/HP) cord specifically developed for encapsulated perforating systems, back-off or other “down hole” exposed service systems. It is our best detonating cord for use in caustic environments. The detonating cord utilizes the highest purity HMX explosive feedstock commercially available, “shrinkage resistant” construction and a special high temperature jacket. This jacket allows the cord to be exposed to well bore fluids at temperature and pressure.
 
Transportation, Storage and Handling
 
• For maximum shelf-life, detonating cord must be stored in cool, dry, well-ventilated magazines. Explosives inventory should be rotated. Use older in Recommended shelf life, under proper storage conditions, is five (5) years from date of manufacture.
• FIRELINE detonating cords must be transported, stored, handled and used in conformity with all federal, state, provincial and local laws and regulations.
 
Application Recommendations
 
• This product is recommended for exposure to well bore fluids.
• ALWAYS cut FIRELINE 17/80 HMX LS EXPOSED detonating cord with a razor blade.
• NEVER attempt to cut FIRELINE 17/80 HMX LS EXPOSED detonating cord with a blow from a sharp or blunt object, such as an axe, pipe wrench, or rock.
• NEVER saw FIRELINE 17/80 HMX LS EXPOSED detonating cord; it may explode and kill or injure.
• NEVER cut detonating cord with devices that produce metal-to-metal contact, such as scissors, wire cutters, crimpers or similar instruments.