Dyno Nobel Inc.

FIRELINE 17/80 HMX LS

FIRELINE 17/80 HMX LS is designed to be used in carrier-based perforating systems within HMX time and temperature operating ranges, where the jacket is protected or not exposed to pressure and/or fluids. Tubing or wireline conveyed perforating systems shall be employed within time and temperature limits (see graph). Nylon jacket limitations will not normally permit this product to be used in exposed applications within HMX application ranges.

FIRELINE 17/80 HMX LS
FIRELINE 17/80 HMX LS is designed to be used in carrier-based perforating systems within HMX time and temperature operating ranges, where the jacket is protected or not exposed to pressure and/or fluids. Tubing or wireline conveyed perforating systems shall be employed within time and temperature limits (see graph). Nylon jacket limitations will not normally permit this product to be used in exposed applications within HMX application ranges.
 
Transportation, Storage and Handling
 
• For maximum shelf-life, detonating cord must be stored in cool, dry, well-ventilated Recommended shelf life, under proper storage conditions, is five (5) years from date of manufacture.
• FIRELINE 17/80 HMX LS detonating cords must be transported, stored, handled and used in conformity with all federal, state, provincial and local laws and regulations.
 
Application Recommendations
 
• This product is not recommended for exposure to well bore fluids.
• ALWAYS cut FIRELINE 17/80 HMX LS detonating cord with a sharp knife.
• NEVER attempt to cut FIRELINE 17/80 HMX LS detonating cord with a blow from a sharp or blunt object, such as an axe, pipe wrench, or rock.
• NEVER saw FIRELINE 17/80 HMX LS detonating cord; it may explode and kill or injure.
• NEVER cut detonating cord with devices that produce metal-to-metal contact, such as scissors, wire cutters, crimpers or similar instruments.